New AUX board for TA37 produced before 02/2021 and new test program editor

We came with new upgrade of existing and highly priced test adapter TA37 – Auxiliary Board (AUX). The driving factor was the need to measure HFE / gfs parameters with extremely low currents in nA range.

Basic HW specifications of AUX board:

  • VI source +/-50V / 3A
  • Voltage / Current measurement
  • Hi-side Leakage measurement down to 30nA range with 16bit resolution for measurement

AUX source application functions in new TA37 SW test editor:

   - Used for analog method of hfe measurement on hi-side low level Ib measurement in nA range. (For conditions with low Ic or for Darlington.)

   - Necessary for function of new TA37 SW 

 

Test results example using MX07 matrix:

 

Test results example:

Test results using MX07 matrix

Test results example

 

TA37 new SW test editor:

    - New improved functions for testing hfe, gfs, thermal resistances

    - Possibility to combine test functions for diodes, transistors and thyristors in one test program

    - Full control of DUT OC for MX07 and custom extension matrixes for multiple devices in one package

    - AC measurements use DSP functions for more accurate measurements with parasitic noise

    - Calibration using external DMM for each range with separate constants

    - Easier extension for new functions

    - Standalone function, can be used in UNIMET 1037

Test editor TA37

 

Contact: 

 Jiří Marek        

Jiří Marek

 

Scroll up